The Print command allows you to print the
project data and results summary. You can view the results on-screen, send to a
printer, or print to a file. You can select a specific component of the pier to
print or customize which parts of the results or input data to print. Pier
specific results can only be printed for piers for which a design has been
completed and the results are available.
A typical printout contains your company header, to include
filename, date, etc. The bottom of a printout includes the program name and
input file path, and the design code used.
When the button of Detailed Design Reports is clicked, a new
Preview window will pop up. In the new window, users may select Structure
components, report types, checking points, and click the Submit button.
Detailed design reports will be generated. Besides, the detailed formulas,
intermediate calculations, references from the design code are provided in the
detailed reports.
For AASHTO LRFD code, the program also offers the detailed
design reports for cap, column, and footing of substructures. In the detailed
design reports, the related references of articles, equations, and intermediate
results are exposed. The following detailed design reports are supported. For
footing types, isolated and combined, pile and spread footing are covered.
- Flexural design
check of pier/abutment cap
- Shear design
check of pier/abutment cap
- Cracking control
check of pier/abutment cap
- Fatigue check of
pier/abutment cap
- Shear check of
column( if shear check for column is selected)
- Flexural design of
footing cap
- One-way shear
design check of footing cap
- Two-way shear
design check of footing cap
- Cracking control
check of footing cap
- Fatigue check of
footing cap
Simply click the button of Detailed Design Reports in
Printing dialog, a Preview window will pop up. You may specify what structure
components, points of interests (POI), and what types of code checking are
included.
|